- SIB1 is sent with the periodicity of 80 ms
when SFN mod 8=0 and is repeated when SFN mod 2 =0. In other words, a new SIB1
is sent every 80 ms and within the 80 ms period, the same SIB1 is repeated
every 20 ms. SIB1 is always sent in sub frame 5.
- The MIB is carried on the Broadcast Channel
(BCH) mapped into the Physical Broadcast Channel (PBCH). This is
transmitted with a fixed coding and modulation scheme and can be decoded
after the initial cell search procedure.
- With the information obtained from the MIB the
UE can now decode the Control Format Indicator (CFI), which indicates the
Physical Downlink Control Channel (PDCCH) length. This allows the PDCCH to
be decoded, and searched for Downlink Control Information (DCI) messages.
A DCI message CRC masked with System Information Radio Network Temporary
Identifier (SI-RNTI) indicates that a SIB is carried in the same sub frame.
The SIBs are transmitted in the Broadcast Control Channel (BCCH) logical
channel. Generally, BCCH messages are carried on the Downlink Shared
Channel (DL-SCH) and transmitted on the Physical Downlink Shared Channel
(PDSCH).
Below is
the diagram for SIB-1 for every 10 ms radio frame
SystemInformationBlockType1 {
CellAccessRelatedInfo {
plmn_IdentityList [0] {
plmn_IdentityList
{
mcc[0] =
1
mcc[1] = 2
mcc[2] =
3
mnc[0] =
1
mnc[1] =
2
mnc[2] =
3
}
CellReservedForOperatorUse =
notReserved
}
TrackingAreaCode = {16, 0x32 0x31 }
CellIdentity = {28, 0x00 0x01 0x90 0001xxxx}
CellBarred= notBarred
IntraFreqReselection = notAllowed
csg_Indication = FALSE
}
CellSelectionInfo {
q_RxLevMin = -45
q_RxLevMinOffset = 1
}
p_Max = 23
FreqBandIndicator = 7
SchedulingInfoList [0] {
si_Periodicity = rf64
sib_MappingInfo [0] = sibType3
sib_MappingInfo [1] = sibType4
sib_MappingInfo [2] = sibType5
}
SchedulingInfoList [1] {
si_Periodicity = rf128
sib_MappingInfo [0] = sibType6
sib_MappingInfo [1] = sibType7
sib_MappingInfo [2] = sibType8
}
si_WindowLength = ms5
SystemInfoValueTag = 1
NonCriticalExtension {
NonCriticalExtension
{
cellSelectionInfo_v920 {
q_QualMin_r9 = -24
q_QualMinOffset_r9 = 7
}
}
}
}
ib-MappingInfo
List of the SIBs mapped to this System
Informationmessage. There is no
mapping
|
si-Periodicity
Periodicity of the SI-message in radio frames,
such that rf8 denotes 8 radio frames, rf16 denotes 16 radio frames, and so
on.
|
si-WindowLength
Common SI scheduling window for all SIs. Unit
in milliseconds, where ms1 denotes 1 millisecond, ms2 denotes 2 milliseconds
and so on.
|
systemInfoValueTag
Common for all SIBs other than MIB,
SIB1, SIB10, SIB11
and SIB12. Change of MIB and SIB1 is detected by
acquisition of the corresponding message.
|
trackingAreaCode
A trackingAreaCode
that is common for all the PLMNs listed.
|